7. PROGRAMMING

7.3 List of Programming Items

Parameters

Key operations

Programming

Defaults

Programming ranges

Ref.

items

page

 

 

 

 

Alarm dead

SHIFT

+

°C

0.1

0.1 to 9.9 (%): % programming of scale

11.6

band

(3 sec. or more)

span

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Periodic

 

 

 

Start time

Not

00:00 to 23:59

 

 

 

SHIFT

+

5

programmed

 

 

11.7

data printing

DATAI

Interval time

Not

00H05* to 23H59 *Limited by chart speed.

 

 

 

 

 

 

 

 

programmed

 

 

 

 

 

 

 

Max. 5 digits

values,

alphabetic

 

Engineering

 

 

3

 

 

(Including

numeric

 

SHIFT

+

V

characters, %, /, °C, °F and space)

11.8

unit *

UNIT

 

 

 

 

 

Reflected by “Range No.” programmed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mV, V, °C, k)

 

 

 

 

 

 

6

 

Not

Max. 9 digits (Including numeric values,

 

Tag *

SHIFT

+

alphabetic characters,

°

°

11.9

 

A- Z

 

programmed

%, /, C, F and

 

 

 

 

 

space)

 

 

 

 

 

0

 

6

No.

Not

1 to 5, Five kinds of messages can be

 

 

+

programmed

programmed.

 

 

 

Message

CLEAR

A- Z

 

 

 

11.10

(3 sec. or more)

 

Not

Max. 15 digits

 

 

 

Message

(Including

numeric

values,

alphabetic

 

 

programmed

 

 

 

 

 

 

characters, %, /, °C, °F and space)

 

 

 

 

 

 

 

non, UP bUrn, doWn bUrn

 

 

Burnout *

SHIFT

+

%

non

For channels with voltage range, burnout

11.11

(3 sec. or more)

is disabled (“non”), even if burnout is

 

 

 

 

 

 

 

 

 

 

programmed (up or down).

 

 

Passcode/

SHIFT

 

 

Pass code

non

non (not programmed). For programming,

 

/

use 4 digits from 0 to 9.

 

11.12

 

 

 

keylock

(3 sec. or more)

 

 

 

 

 

 

Key lock

UnLoCkEd

LockEd, UnLoCkEd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time axis

0

9

 

 

 

 

 

 

 

CLEAR

LIST

oFF

on, oFF

 

 

 

9.6

synchronization

(3 sec. or more)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

8

Time

 

0, 0 to 10 (sec.). “0” means no time

 

Input filter*

CLEAR

ALARM

0

11.13

 

(3 sec. or more)

constant

 

constant.

 

 

 

 

 

 

 

SPACE

 

 

Programmed parameters can be copied to

 

 

SHIFT

 

 

 

other channels. Available parameters to be

 

Copy

COPY(=)

 

 

11.14

Programming in each

copied

are [Range/Printing

range],

 

programming mode

 

 

[Engineering unit] and [Tag].

 

 

* Programming is required to each channel. For 1-pen type, programming is only for CH 1. The items without * mark are programming common to all channels. For "alarm", programming is required to each level of channels.

3

Programming for Options

Parameters

Programming

Key operations

Programming

Defaults

Programming ranges

 

Ref.

 

items

 

 

 

contents

 

"0" to "n" (n: 6, 12)*

 

page

 

 

 

 

 

 

 

mode,

 

 

Relay

 

 

8

 

 

In alarm

programming

 

 

SHIFT

 

Relay No.

0

program

relay Nos. (terminal

 

 

No.

ALARM

 

 

 

 

 

 

 

Nos.) for alarm output.

 

 

 

 

 

 

 

 

 

 

 

Alarm

 

 

 

 

 

 

* number of output points

 

 

AND

0

 

 

 

 

AND/OR programming is required

12.1

output

°

AND/OR

or

 

OR

CLEAR

 

C

for each relay No.

 

 

 

(3 sec. or more)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

DISP

 

Relay coil

E

E (energize), d (not energize)

 

Common

 

 

°

Relay output

U

H (hold), U (not hold)

 

to all relay

 

 

mode

 

 

C

 

 

 

(3 sec. or more)

Alarm display

U

H (hold), U (not hold)

 

Nos.

 

 

 

 

 

-35-

Page 39
Image 39
Omega RD2800, RD200 manual Programming for Options