4-6-5 Selecting the Automatic Reset Function

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿-￿￿￿￿￿￿$￿0&￿￿￿￿1￿￿￿￿￿￿￿.￿￿￿￿￿￿-￿￿￿￿￿￿ Section 3-6

[ MEMORY SWITCH MENU (2/2) ]

Automatic Reset

ON

EXIT

 

Data Bit Length

7bits

PREV.

Stop Bit Length

2bits

PAGE

Parity Bit

Odd

SAVE

Flow Control

XON/XOFF

RS-232C Speed

19200bps

EXIT

 

The setting changes when each of the touch switches is pressed are indicated below.

“Automatic Reset”

Alternates between “OFF” and “ON”

“Data Bit Length”

Alternates between “8 bits” and “7 bits”

“Stop Bit Length”

Alternates between “2 bits” and “1 bit”

“Parity Bit”

Changes among “None”, “Even” and “Odd”

“Flow Control”

Changes among “None”, “RS/CS”

 

and “XON/XOFF”

“RS-232C Speed”

Changes among “2400 bps”, “4800 bps”,

 

“9600 bps” and “19200 bps”

To set and quit the menu, press the [SAVE EXIT] touch switch. To quit without set- ting, press [EXIT].

4-6-5 Selecting the Automatic Reset Function

The “Automatic Reset” memory switch in MEMORY SWITCH MENU 2 selects whether or not operation is automatically restarted after the occurrence of a com- munication error.

The factory setting for the automatic reset function is “OFF”.

Select whether the automatic reset function is off or on by operation from the Sys- tem Menu as described below.

[ SYSTEM MENU ]

Quit

Transmit Mode Maintenance Mode

Select “Maintenance Mode”.

￿￿

Page 104
Image 104
Omron V022-E3-1 operation manual 4-6-5Selecting the Automatic Reset Function