Omron V022-E3-1 7-3-3Lamps and Touch Switches, digitNumber Input Notify, Section, Description

Models: V022-E3-1

1 318
Download 318 pages 5.12 Kb
Page 233
Image 233
8-digit Number Input Notify

￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿

Section 6-3

 

Description

A number with 4 transferred digits set with the NT600S number setting function is

 

reported to the Host with this command.

 

 

8-digit Number Input Notify

Format

[ESC]

1B

F

d1

d2

d3

n1

n2

n3

n4

n5

 

 

 

 

 

 

 

 

 

46

 

 

n6

n7

n8

[CR]

 

 

 

 

 

0D

 

 

 

 

 

 

 

 

 

 

 

 

d1d2d3: Numeral memory table address to which number was input (3-digit hex-

 

 

adecimal)

 

 

 

 

000 to 1FFH

 

 

 

n1n2n3n4n5n6n7n8: Input number data (8-digit BCD)

Description

A number with 8 transferred digits set with the PT number setting function is re-

 

ported to the Host with this command.

7-3-3 Lamps and Touch Switches

Notifying the Display Status The lit/flashing status of the lamps and touch switches which are set on the screen currently displayed on the NT600S is sent to the Host by executing the following command.

Lamp and Touch Switch Display Status Response

Format

[ESC] S m1 n1 n2 n3

1B

53

m1: Display status

m1

Display status

0 (30H)

Not lit (normal display)

1 (31H)

Lit

2 (32H)

Flashing inverse

 

 

n1n2n3: Lamp or touch switch address (3-digit hexadecimal)

 

 

000 to 0FFH (0 to 255)

Description

 

The NT600S returns this command to report the lamp or touch switch number dis-

 

 

play status to the Host in response to the Lamp and Touch Switch Display Status

 

 

Enquiry Command (see 7-2-3) sent from the Host.

 

 

 

 

Reference Lamps 0 to 111 are reported as being lit when in the “flashing inverse” status.

 

 

 

￿￿￿

Page 233
Image 233