Controlling the NT600S Status by Using Allocated Bits and Words ..... PT Status Control Area (PC to PT)

The PT status control area (PC to PT) is provided to control the NT600S status from the PC. When data is written to this area in the PC, the NT600S will read the data and operates according to the data. The PT status control area is configured as four consecutive words as shown below.

Word 15

14

13

 

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n

 

 

 

 

 

 

 

 

 

Screen # (4-digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n+1

 

 

0

 

 

 

 

Copy source memory table # (3-digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

n+2

 

Copy type

 

 

Copy destination memory table # (3-digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n+3

 

 

 

PT status control bit

 

 

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit

Screen switch setting

Copy memory table setting

PT status control

Reference The first word (word n) of the PT status control area must be set with the support tool.

Screen switch settings (refer to page 160)

￿Specify the screen # to switch the screen displayed on the NT600S. Copy memory table settings (refer to page 175)

Specify the memory table # to copy the contents of a memory table internally in the NT600S.

Set the copy type to match the type of memory table to be copied: 0: Character-string memory table

￿1: Numeral table

PT status control bits (refer to page 192)

Turn this bit ON and OFF to control the buzzer and backlight of the NT600S.

n+3 CH

15

14

13

12

11

10

9

8

Bit

 

 

 

 

0

0

0

 

 

Item Controlled

1 (ON)

0 (OFF)

 

 

 

Screen display

ON

OFF

(Note 1)

 

 

 

 

 

Processing priority

 

 

registration

ON

OFF

(Note 2)

 

 

 

 

 

Continuous buzzer

ON

OFF

 

 

 

Intermittent buzzer

ON

OFF

 

 

 

Backlight mode

ON

Flash

(Note 3)

 

 

 

 

 

Note 1: When “ON” is set for screen display, the backlight/EL display is on; when “OFF” is set for screen display, the backlight is off.

Note 2: Priority registration is only valid when NT link (1:N) is set.

Note 3: Cannot be used with NT600S-ST211.

￿￿￿