3-7-2 Connection Method

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿$￿-￿￿￿￿"￿￿&￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Section 2-7

 

 

 

 

 

Reference ￿If unit numbers 8 and 9 are set with a C￿￿H, a “special I/O unit error” occurs.

When an NT600S is connected to a C H, I/O expansion equipment cannot be connected. In other words, it will not be possible to connect other special I/O units, and therefore whatever unit numbers are specified there will be no du- plication of numbers.

3-7-2 Connection Method

Using the I/O connecting cable, connect the C200H interface unit mounted to the

NT600S and the PC unit.

[I/O connecting cable] Caution Always turn off the power at both the PC and PT before connecting the C200H interface cable.

￿Otherwise the system may operate unpredictably.

Switch off the power to the NT600S and PC before disconnecting/connecting the cable.

[I/O connecting cable]

Use one of the following models of I/O connecting cable.

 

Model

Cable length (L)

 

 

 

 

C200H-CN311

30cm

 

 

 

 

NT20M-CNP711

70cm

 

C200H-CN711

 

 

For connecting C200H/

NT20M-CNP221

2m

C200H-CN221

HS/HE/HG/HX

 

NT20M-CNP521

5m

 

 

C200H-CN521

 

 

 

NT20M-CNP131

10m

 

C200H-CN131

 

 

 

C20H-CN312

30cm

 

 

 

 

NT20M-CNP712

70cm

For connecting C H

C20H-CN712

 

 

NT20M-CNP222

2m

 

C20H-CN222

 

 

Manual background Caution

Note

In the case of NT20M-CNP￿￿￿models, the connector at the C200H interface side is a compact one.

The combined lengths of each of the I/O connecting cables must not exceed a total of 12 m (or 6 m for C￿￿H models).

The cable’s tensile load is 30 N. Do not subject it to loads greater than this.

￿Otherwise a discontinuity may occur, causing operation to fail.

If the I/O connecting cable is passed through a hole, this hole must have a diam- eter of at least 53 mm ￿. If the top cover is removed the cable can be passed through a minimum hole size of 33 mm ￿. Replace the cover before mounting

￿the unit.

If a C200H-CN￿￿￿or C20H-CN￿￿￿is used as the I/O connection cable, the connector will project beyond the bottom face of the NT600S.

￿￿