Wiring Method

￿￿￿￿￿￿￿￿￿￿￿￿￿$￿￿￿￿￿￿￿'￿￿()*+￿,

Section 2-6

Wiring Method

For the connections between the PC and NT600S units, wire as shown below. The wiring￿ method differs depending on the cables used for connection.

RS-422A connection

RS-232C cable (max. length: 2 m), or directly connected RS-422A cable

C200HX/HG/HE

OMRON PC

While controlling machinery and monitoring lines, controls the NT600S units when necessary. C200H/HG/HE can be used.

RS-232C/RS-422A

RS-232C/RS-422A

converter unit,

converter unit,

type NT-AL001

type NT-AL001

RS-232C/RS-422A converter unit, type NT-AL001

RS-232C/RS-422A converter unit, type NT-AL001

RS-232C/RS-422A converter unit, type NT-AL001

RS-422A cable (*)

RS-422A cable (*)

RS-422A cable (*)

RS-422A cable (*)

RS-232C cable

RS-232C cable

RS-232C cable

RS-232C cable

(max. length: 2 m)

(max. length: 2 m)

(max. length: 2 m)

(max. length: 2 m)

NT600SNT600SNT600SNT600S

(*) Total cable length: 500 m

[RS-232C Cable Wiring] (NT600S-ST211(B)-EV￿)

PT, PC

 

Abbrev.

Pin No.

 

 

 

 

 

Connector

 

 

cover

 

SD

2

RS-232C

RD

3

interface

 

 

RS

4

 

 

CS

5

 

+5V

6

 

SG

9

NT-AL001

Pin No.

Abbrev.

Connector cover

2

SD

 

3

RD

RS-232C

4

RS

interface

 

5

CS

 

6

+5V

 

9

SG

 

Shielding

: Only connected at PC

wire

 

 

The pin numbers are the numbers at the NT600S.

For the pin numbers at the PC, refer to the manual for the PC used.

￿￿

Page 64
Image 64
Omron V022-E3-1 operation manual Section, RS-422Aconnection, Wiring Method