System Menu Display Permission

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿&￿￿￿

Section 6-2

Displaying the System Menu By using the following command, it is possible to enable or disable display of the NT600S system menu.

System Menu Display Permission

Format

[ESC] W m1

1B

57

 

m1: System menu display permission/inhibition

 

0

(30H): Display permitted

 

1

(31H): Display inhibited

Description

System menu is displayed when “display permitted” is set, and from the system

 

menu, selection of transmit mode or maintenance mode is possible. If “display in-

 

hibited” is set, the system menu is not displayed.

Enquiry of the Battery Voltage Status

To check the voltage status of the built-in NT600S battery, use the following com- mand.

Reference The battery is optional.

PT Status Enquiry

Format

[ESC] Z

1B

5A

Description

Determines if the built-in PT battery voltage is low.

 

The PT returns the PT Battery Status Response Command (see 7-3 PT Battery

 

Status Response) to report the battery status.

Whether or not report is made is determined by the ON/OFF setting of DIW

SW2-8.

Initializing the Display History Data Memory

The display history record stored in the NT600S can be cleared (initialized) by giv- ing the following command from the Host.

For details of the display history function, refer to Display History (page 110).

Initialize Display History

Format

[ESC] ]

1B

5D

Description

￿Deletes the entire contents of the display history.

￿￿￿