Omron V022-E3-1 operation manual Section, Omron

Models: V022-E3-1

1 318
Download 318 pages 5.12 Kb
Page 151
Image 151
OMRON

￿￿￿￿￿

Section 4-6

When a lamp is overlapped with a memory table display

The guide display message for a lamp is a fixed character-string. If you want to change the lamp guide display in accordance with some condition, overlap the dis- play area of a numeral memory table or character-string memory table with the lamp. However, note that -- as shown below -- different results will be achieved depending on the timing of the lighting of the lamp and the updating of the memory table. Bear this in mind when creating the control program.

Example 1 :Lamp lit after the memory table is updated

Lamp OFFLamp OFFLamp ON

OMRON

PT

PT

Memory table

 

Lamp turned

updated

 

ON

Lamp Character-string memory

 

The characters are

table display area

 

displayed white on black.

Example 2 :Memory table updated while lamp is lit

Lamp OFF

Lamp ON

Lamp ON

OMRON

OMRON

PT

 

Lamp turned

Memory table

 

ON

updated

Lamp

Character-string memory

The characters are

 

table display area

displayed white on black.

The memory table display area of the lit lamp is overwritten.

￿￿￿