Omron V022-E3-1 operation manual Section, Overrun Error

Models: V022-E3-1

1 318
Download 318 pages 5.12 Kb
Page 259
Image 259
Overrun Error

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿6￿￿￿￿.￿￿￿￿￿￿￿

Section 7-2

 

 

 

 

 

Message

Cause

Remedy

 

 

 

 

 

Parity Error

Communication parameters set

Check whether the parity bit, data bit length, baud

 

Framing Error

incorrectly.

rate, stop bit length, and flow control settings of the

 

 

PC/Host match the settings of the NT600S.

 

Overrun Error

 

 

 

 

 

Noise caused data corruption during

Use a noise-resistant cable if communication occurs

 

Overflow Error

 

communication.

in an environment with high levels of noise.

 

 

 

 

 

 

 

 

The connectors of the connecting

Reconnect the cable.

 

 

cable are not connected correctly.

 

 

 

 

 

 

Buffer Overflow

The NT600S receive buffer is full.

Lengthen the command transmission intervals. If this

 

 

 

error occurs frequently, set flow control for

 

 

 

communications.

 

 

 

 

 

Time Out

The connectors of the connecting

Reconnect the cable.

 

 

cable have become disconnected.

 

 

 

The PC/Host is stopped.

Make sure the PC/Host is able to communicate with

 

 

 

the NT600S.

 

 

During transmission of one

Confirm the proper command length.

 

 

command, a time lapse exceeding 5

Check the cable connection.

 

 

seconds is detected.

 

 

 

 

 

 

NAK Received

Noise caused data corruption during

Use a noise-resistant cable if communication occurs

 

(end code simultaneously

communication.

in an environment with high levels of noise.

 

displayed)

 

Check the end code by referring to the PC user’s

 

 

 

 

 

 

manual.

 

 

 

 

 

Unit No. Error

The unit No. does not match that set

Set the PC unit No. to “0”.

 

 

on the PC.

 

 

 

 

 

 

 

The PC is transmitting incorrect data.

Check PC operation.

 

 

 

 

 

 

Noise caused data corruption during

Use a noise-resistant cable if communication occurs

 

 

communication.

in an environment with high levels of noise.

 

FCS Error

The PC is transmitting incorrect data.

Check PC operation.

 

Sum Error

 

 

 

Noise caused data corruption during

Use a noise-resistant cable if communication occurs

 

 

communication.

in an environment with high levels of noise.

 

End Code Error

There ￿is an error at the NT600S or

Contact your OMRON service center.

 

 

the C200H interface unit.

 

 

If an error occurs during the execution of a command, that command becomes invalid and it is not executed.

￿￿￿

Page 259
Image 259
Omron V022-E3-1 operation manual Section, Overrun Error