Omron V022-E3-1 operation manual Selecting the Host Communication Method, 4-6-1

Models: V022-E3-1

1 318
Download 318 pages 5.12 Kb
Page 99
Image 99
4-6-1

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

-￿￿￿￿￿￿$￿0&￿￿￿￿1￿￿￿￿￿￿￿.￿￿￿￿￿￿-￿￿￿￿￿￿ Section 3-6

 

RS-232C method

 

 

 

[ MEMORY SWITCH MENU (2/2) ]

EXIT

 

Automatic Reset

ON

 

 

 

Data Bit Length

7bits

PREV.

 

Stop Bit Length

2bits

 

PAGE

 

Parity Bit

 

Odd

SAVE

 

Flow Control

XON/XOFF

 

RS-232C Speed

19200bps

EXIT

 

 

 

Automatic Reset

Selecting the Automatic Reset Function (page 90)

 

Host Link Speed

Selecting the Host Link Communication Speed (page 86)

 

PT UNIT No.

Setting the PT UNIT No. (page 87)

 

Data Bit Length

Setting the RS-232C Communication Conditions (page 89)

 

Stop Bit Length

Setting the RS-232C Communication Conditions (page 89)

 

Parity Bit

 

Setting the RS-232C Communication Conditions (page 89)

 

Flow Control

Setting the RS-232C Communication Conditions (page 89)

 

RS-232C Speed

Setting the RS-232C Communication Conditions (page 89)

4-6-1

Selecting the Host Communication Method

 

The NT600S can be connected to a PC/Host by the host link, NT link (1:1, 1:N),

 

C200H direct, or RS-232C. Either link can be selected by setting the “Comm.

 

Method” memory switch. The factory setting has been made to the “Host link”.

Select the host communication method by the menu operation from the System

Menu as mentioned below.

[ SYSTEM MENU ] Quit

Transmit Mode Maintenance Mode

Select “Maintenance Mode”.

 

Select “Memory Switches”.

[ MAINTENANCE MENU ]

Quit

Display History

PT Setting Status

 

I/O Check

 

Memory Init.

 

Memory Switches

 

￿￿

Page 99
Image 99
Omron V022-E3-1 operation manual Selecting the Host Communication Method, 4-6-1