3-6-3 PC Switch Settings

￿￿￿￿￿￿￿￿￿￿￿￿￿$￿￿￿￿￿￿￿'￿￿()*+￿,

Section 2-6

3-6-3 PC Switch Settings

When the PC and NT600S units have been connected, set the switches at the CPU module at the PC side in order to enable communication using the NT link ￿method.

C series, C200HX/HG/HE

Write the communication conditions directly to the “PC system area” (data memory) using a peripheral tool (e.g., SYSMAC support software). For details on the operation for setting the “PC system area”, refer to the “SYSMAC C200HX/ HG/HE Installation Guide” (W302-E1-￿).

[PC system setting area setting]

With C200HX/HG/HE, the setting area differs according to the standard port of the CPU module used for the connection or the port of the expansion communication board.

Port

Channel #

Writing Value

Settings

 

 

 

 

C200HX/HG/HE

DM6645

 

Use NT link (1:N)

RS-232C port

 

 

 

= highest unit No.

 

 

 

C200HX/HG/HE

 

 

DM6555

5￿00

in the maximum

port A

 

 

number of connect-

C200HX/HG/HE

DM6550

 

able PTs (1 to 7). (*)

 

 

port B

 

 

 

 

 

(*) When using C200HE, the PT unit No. range is 1 to 3.

￿￿