Removing the unit

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿$￿-￿￿￿￿"￿￿&￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Section 2-7

 

Removing the unit

As shown in the figure below, grasp the unit by the cutouts at either side, then pull it

 

out while keeping a firm grip.

 

 

C200H Interface Unit Switch Settings

Set all the DIP switches (SW1, SW2) of the C200H interface unit to “OFF” (re- served for system use) and set the unit number to 0 with the rotary switch (SW3).

It is necessary to set a machine number for NT600S since it operates as a high- level function I/O unit of C200H. Make sure that the machine number to be allo- cated is unique.

Switch cover

SW1 SW2 SW3

The DIP switches are located under the switch cover on the front of the interface unit.

When using C200H/HS, or C200HX/HG/HE, the words corresponding to the channel numbers indicated below are occupied for each unit number set. Howev- er, since the NT600S uses the allocated bits and words for processing, it does not use these words.

These words are used as internal auxiliary relays.

Unit No.

Channel #

 

 

0

100 to 109

 

 

1

110 to 119

 

 

2

120 to 129

 

 

3

130 to 139

 

 

4

140 to 149

 

 

5

150 to 159

 

 

6

160 to 169

 

 

7

170 to 179

 

 

8 (*)

180 to 189

 

 

9 (*)

190 to 199

 

 

(*) Cannot be set with C

H.

￿￿