Disabling/Enabling the Touch Switch Input

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿&￿￿￿

Section 6-2

 

Description

Enquires the status of a lamp or touch switch specified by its address.

 

The NT600S returns the Lamp and Touch Switch Display Status Response Com-

 

mand (refer to 7-3 Lamp and Touch Switch Display Status Response) to report the

 

display status.

Disabling/Enabling the Touch Switch Input

It is possible to enable or disable input from the touch switches on the displayed screen.

The following commands are used for this control.

Touch Switch Disable

Format

[ESC] U m1

1B

55

 

 

m1: Switch whose input is to be disabled.

 

 

0 (30H): Touch switches

 

 

2 (32H): Touch switches

Description

 

Disables touch switch and function key input and notification to the Host.

 

 

 

 

Reference Use the Touch Switch Enable Command (refer to 7-2-3 Touch Switch Enable) to

 

 

use a disabled touch switch again. Disabled touch switches are also enabled

 

 

when the NT600S power is turned off.

 

 

 

Touch Switch Enable

Format

[ESC] V m1

1B

56

 

 

m1: Switch whose input is to be enabled.

 

 

0 (30H): Touch switches

 

 

2 (32H): Touch switches

Description

 

Enables input and notification to the Host of a disabled touch switch or function

 

 

key.

 

 

 

 

Reference Disabled touch switches are also enabled when the NT600S power is turned off.

 

 

 

￿￿￿

Page 228