Order for writing to the PT status control area (PC to PT)

First write the “copy destination memory table number”, and then, write the “copy source memory table number” to the PT status control area (PC to PT).

The NT600S reads the area sometimes when the PC is writing the settings. If the “copy source memory table number” has been written first and is changed, unex-

￿pected memory table may possibly be changed. Allocated words that the NT600S reads

The NT600S reads the allocated words in the PC for the memory tables which need to be displayed. If the copy source memory table is allocated to a PC word,

￿it may sometimes be used at the initialization only. Use of the “copy type”

Copy will not be executed when the “copy type” is other than “0” or “1”. The memory table copy is executed only when the contents of the area are changed. To repeat copying of the same copy source and same copy destination, write a

￿value other than “0” or “1” for the copy type, and then, write a correct value again. Copying a numeral memory table

If the display method or the number of registered words include discrepancies, a numeral memory table may not be copied and displayed correctly.

Application Example of Copying of a Character-String Memory Table

This example gives a PC program to switch the character-string display on the screen by using the memory table copy operation as the allocated bit is turned ON ￿and OFF.

Support tool settings

Allocate the memory as shown below by using the support tool.

PT status control area allocation: Word 0100

Contents registered to the screen: Character-string memory table #4

Line 1

Normal

Character-string memory table #4

Character-string memory table settings

#

Contents

Number of

Character Digits

 

 

 

 

 

4

Normal

6 digits

 

 

 

10

Error

6 digits

 

 

 

11

Normal

6 digits

 

 

 

￿￿￿

Page 191