4-8-5 Setting the Support Tool Mode

2￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Section 3-8

[ MEMORY SWITCH MENU (1/2) ]

Comm. Method

Host Link

EXIT

 

Key Press Sound

OFF

NEXT

Buzzer Sound

OFF

PAGE

Putting-Out Time

None

SAVE

Resume Function

ON

Support Tool Mode

NT600S

EXIT

 

Each time the “Resume Func- tion” touch switch is pressed, the setting option changes from “ON” to “OFF” or “OFF” to “ON”.

To set and quit the menu, press the [SAVE EXIT] touch switch. To quit without setting,￿press [EXIT].

When “OFF” is set, the resume function is ineffective, and the memory tables are initialized when the NT600S is switched ON or reset, and on switching to the run mode. When new memory table data (initial settings) is transmitted from the

￿support tool, the contents of the memory tables are also updated.

When “ON” is set, the resume function is effective, and even when the NT600S is switched ON or reset, or switched to the run mode, the memory tables retain their existing data.

When NT600S operation starts, the contents of the memory tables are also writ- ten to the allocated words at the host. In addition, when new memory table data (initial settings) is written from the support tool, the initial settings are updated, but the memory tables themselves retain their original contents. To initialize with new initial settings, carry out memory table initialization (page 75).

4-8-5 Setting the Support Tool Mode

By setting the “Support Tool Mode” to “NT600M”, the NT600S can be used in the same way as the existing NT600M model, and is made compatible with the NT20M/NT2000M/NT600M support tool (Ver.4).

However, the following restrictions apply when the “NT600M” setting option is se- lected.

Version 5 of the direct connection function cannot be used.

The “PT type” setting must be set to “NT600M”.

High-speed transmissions with respect to the support tool are not possible.

￿Transmissions consisting of direct information only are not possible.

When screen data transmission is in screen units, simultaneous transmission of multiple screens is not possible. An attempt to transmit multiple screens may destroy the screen data.

When screen data transmission is in screen units, transmission with verification set is not possible.

￿Before transmitting data in file units, the screen data memory must be initialized. It is not possible to create screen data for RS-232C communication.

￿￿

Page 113
Image 113
Omron V022-E3-1 operation manual 4-8-5Setting the Support Tool Mode, Section