MC55 AT Command Set

7.13 ATS7

s

mobile

7.13

ATS7 Set number of seconds to wait for connection completion

Syntax

Read Command

ATS7?

Response(s)

<n>

OK

Write Command

ATS7=<n>

Response(s)

OK

PIN ASC0 ASC1 MUX1 MUX2 MUX3

￿ ￿ ￿ ￿ ￿ ￿

Reference(s)

V.25ter

Command Description

This parameter setting determines the amount of time to wait for the connection completion when answering or originating a call.

Parameter Description

<n>(num)(&W)(&V)

no. of seconds to wait for connection completion 000...060(&F)

Notes

Values bigger than 60 cause no error, but <n> will be set down to maximum value of 60.

In <n> of ATS0 of the called party is set to higher values the call establishment may not be successful.

The correlation between ATS7 and ATS0 is important.

Example: ATS7=30 and ATS0=20 may not allow call establishment.

MC55_ATC_V01.05

Page 156 of 469

2/10/04

Confidential / Released

 

 

Page 156
Image 156
Siemens MC55 manual ATS7?, ATS7=n