MC55 AT Command Set

7.21 AT+CRLP

<mws>(num)(&W)(&V)

Mobile window size (MS to IWF) 0...[10]...61(&F)

s

mobile

<T1>(num)(&W)(&V)

Acknowledgement timer (T1 in 10 ms units) 48...[78](&F)...255

<N2>(num)(&W)(&V)

Re-transmission attempts N2 1...[6](&F)...255

<verx>(num)

0

RLP version number in integer format; when version indication is not present it

 

shall equal 0.

Notes

RLP version 0: single-link basic version;

RLP version 1: single-link extended version (e.g. extended by data compression);

RLP version 2: multi-link version.

Compression and multi-link are not supported.