MC55 AT Command Set

12.24 AT^SSMSS

s

mobile

12.24AT^SSMSS Set Short Message Storage Sequence

Syntax

Test Command

AT^SSMSS=?

Response(s)

^SSMSS: (list of supported) <seq>s

Read Command

AT^SSMSS?

Response(s)

^SSMSS: <seq>

OK

Write Command

AT^SSMSS=<seq>

Response(s)

OK

 

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

 

 

￿

￿

￿

￿

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference(s)

SIEMENS

Command Description

The short message storage ''MT'' (see AT+CPMS) is a logical storage. It consists of two physical storages ''ME'' and ''SM''. This command allows to select the sequence of addressing this storage.

Parameter Description

<seq>(num) MT sequence

0(&F)

''MT'' storage is ''ME'' then ''SM

1

''MT'' storage is ''SM'' then ''ME''

Note

Access to the SIM storage is faster. For compatibility with previous software re-leases, the ''MT'' sequence <seq>=0 is the factory default.