MC55 AT Command Set

16.9 AT^SNFA

s

mobile

16.9AT^SNFA Set or query of microphone attenuation

Syntax

Test Command

AT^SNFA=?

Response(s)

^SNFA: (list of supported <atten>s)

OK

Read Command

AT^SNFA?

Response(s)

^SNFA: <atten>

OK

Write Command

AT^SNFA=<atten>

Response(s)

OK

ERROR

CME ERROR: <err>

 

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

 

 

￿

￿

￿

￿

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference(s)

SIEMENS

Command Description

The test command returns the supported values of the parameter <atten>.

The read command returns the current attenuation value on the microphone path for the current audio device (selected by AT^SNFS).

Write command controls the large-scale attenuation on the microphone path for the current audio device (selected by AT^SNFS) with the following restrictions:

It is not allowed for audio device 1

As long as the microphone is muted, the write command is temporarily disabled

Setting of value 0 is not allowed (use AT^SNFM=0 for this).

For values greater than 32767, 32767 will be used.

MC55_ATC_V01.05

Page 403 of 469

2/10/04

Confidential / Released

 

 

Page 403
Image 403