MC55 AT Command Set

16.15 AT^SNFS

Examples

EXAMPLE 1

s

mobile

Suppose a user wishes to use alternatively a handsfree device and a handset. The handset can be connected to the first analog interface and adjusted to audio mode 4. The handsfree device can be attached to the sec- ond analog interface and adjusted to audio mode 2. The factory defaults of AT^SAIC need not be changed. Settings for the handset:

AT^SNFS=4

 

OK

 

AT^SAIC?

Factory default of AT^SAIC assigned to audio mode 4.

^SAIC: 2,1,1

 

OK

 

 

 

Settings for the handsfree device:

 

 

 

AT^SNFS=2

 

OK

 

AT^SAIC?

Factory default of AT^SAIC assigned to audio mode 2.

^SAIC: 2,2,2

 

OK

 

 

 

To store the configuration to the user defined audio profile:

AT^SNFW

Stores the audio mode and the interface.

OK

 

 

 

To switch back and forth:

 

 

 

AT^SNFS=4

Switches to the handset connected to analog interface 1.

OK

 

AT^SNFS=2

Switches to the handsfree device at analog interface 2.

OK

 

 

 

EXAMPLE 2

The following example illustrates a combination of a handset and a handsfree device connected to other inter- faces than those assumed as factory default.

Settings for a handset connected to the second analog interface and adjusted to audio mode 4:

AT^SNFS=4

OK

AT^SAIC=2,2,2

OK

MC55_ATC_V01.05

Page 415 of 469

2/10/04

Confidential / Released

 

 

Page 415
Image 415
Siemens MC55 manual ATSNFS=4 ATSAIC?, ATSNFS=2 ATSAIC?, Atsnfw