MC55 AT Command Set

16.17 AT^SNFV

s

mobile

16.17AT^SNFV Set loudspeaker volume

Syntax

Test Command

AT^SNFV=?

Response(s)

^SNFV: (list of supported <outStep>s)

OK

Read Command

AT^SNFV?

Response(s)

^SNFV: <outStep>

OK

Write Command

AT^SNFV=<outStep>

Response(s)

OK ERROR +CME ERROR

PIN ASC0 ASC1 MUX1 MUX2 MUX3

￿ ￿ ￿ ￿ ￿ ￿

Reference(s)

SIEMENS

Command Description

The test command returns the supported values of the parameter <outStep>.

The read command returns the current value of parameter <outStep>.

The write command can be used to set the volume of the loudspeaker to the value <outCalibrate> addressed by <outStep>.

Parameter Description

<outStep>(num)

The actual volume of each step is defined by the parameter <outCalibrate>, which can be set with AT^SNFO. 0...4(P)

MC55_ATC_V01.05

Page 419 of 469

2/10/04

Confidential / Released

 

 

Page 419
Image 419
Siemens MC55 manual Atsnfv Set loudspeaker volume, Atsnfv=?, Atsnfv?, Snfv outStep, ATSNFV=outStep