MC55 AT Command Set

8.6 AT^MONI

s

mobile

8.6AT^MONI Monitor idle mode and dedicated mode

Syntax

Test Command

AT^MONI=?

Response(s)

^MONI:(list of supported <period>s)

OK

Exec Command

AT^MONI

Response(s)

See: 8.6.1

OK

Write Command

AT^MONI=<period>

Response(s)

See: 8.6.1

OK

 

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

 

 

￿

￿

￿

￿

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference(s)

SIEMENS

Command Description

The execute command can be used to retrieve the cell parameters of the serving/dedicated cell on request.

The write command can be used to retrieve information of the serving/dedicated cell automatically every <period> seconds. To stop the presentation type "AT" or "at".

Parameter Description

<period>(num)

Display period in seconds 1...254

Notes

The two header lines (see 8.6.1) are output after every ten data lines.

MC55_ATC_V01.05

Page 197 of 469

2/10/04

Confidential / Released

 

 

Page 197
Image 197
Siemens MC55 manual Atmoni Monitor idle mode and dedicated mode, Atmoni=?, ATMONI=period, Periodnum