MC55 AT Command Set

3.4 AT+CEER

s

mobile

Number

Description

26

Insufficient resources

27

Unknown or missing access point name

28

Unknown PDP address or PDP type

29

User authentification failed

30

Activation rejected by GGSN

31

Activation rejected, unspecified

32

Service option not supported

33

Requested service option not subscribed

34

Service option temporarily out of order

35

NSAPI already used

36

Regular PDP context deactivation

37

QoS not accepted

38

Network failure

39

Reactivation requested

40

Feature not supported

Causes related to invalid messages

81

Invalid transaction identifier value

95

Semantically incorrect message

96

Invalid mandatory information

97

Message type non-existant or not implemented

98

Message type not comaptible with protocol state

99

Information element non-existent or not implemented

100

Conditional information element error

101

Message not compatible with protocol

111

Protocol error, unspecified

 

 

3.4.11SIEMENS release cause for Session Management (SM)

Number

Description

3

The MS has not got any answer to the ACTIVATE PDP CONTEXT request message sent five

 

times to the network

4

A MT PDP context which is active or in the activation process is deactivated because another

 

MT PDP context with the same TI is requested by the network to be activated

5

A MT PDP context which is active or in the activation process is deactivated because another

 

MT PDP context with the same TI is requested by the network to be activated. The activation

 

request is rejected by the SM sending the cause 'insufficient resources' to the network

 

because the SM was not able to perform the necessary comparisons for a static PDP address

 

collision detection.

 

 

MC55_ATC_V01.05

Page 83 of 469

2/10/04

Confidential / Released

 

 

Page 83
Image 83
Siemens MC55 manual Siemens release cause for Session Management SM