MC55 AT Command Set

17.5 AT^SCTM

s

mobile

17.5AT^SCTM Set critical operating temperature presentation mode or query temperature

Use this command to monitor the temperature range of the module and the battery. The write command enables or disables the presentation of URCs to report critical temperature limits.

CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report mode: URCs can be always displayed regardless of the selected mode <n>.

Syntax

Test Command

AT^SCTM=?

Response(s)

^SCTM:(list of supported <n>s)

OK

Read Command

AT^SCTM?

Response(s)

^SCTM: <n>, <m>

OK ERROR

+CME ERROR: <err>

Write Command

AT^SCTM=<n>

Response(s)

OK ERROR

+CME ERROR: <err>

PIN ASC0 ASC1 MUX1 MUX2 MUX3

￿ ￿ ￿ ￿ ￿ ￿

Reference(s)

SIEMENS

Unsolicited Result Codes

URC 1

URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level, or when it is back to normal.

MC55_ATC_V01.05

Page 434 of 469

2/10/04

Confidential / Released

 

 

Page 434
Image 434
Siemens MC55 manual Atsctm=?, Atsctm?, Sctm n, m, ATSCTM=n