MC55 AT Command Set

16.12 AT^SNFM

s

mobile

Parameter Description

<MicSwitch>(num)

Microphone mute control parameter.

Evaluated during voice calls and if <MicVccCtl> is omitted only, e.g. AT^SNFM=1. Command does not depend on audio mode.

0

Mutes the microphone.

1(P)

Activates the microphone.

<MicVccCtl>(num)

Microphone supply voltage control parameter. Setting applies to microphone input 2 only.

CME error is given if <MicSwitch> is not omitted. Enter for example AT^SNFM=,1 or AT^SNFM=,2.

0

Supply voltage is always switched off.

1

Supply voltage is always switched on.

2(P)

Supply voltage state during voice calls is controlled by the ME. Actual value is

 

determined by parameter data set of the selected audio mode.

<MicVccState>(num)

Microphone supply voltage control status.

0

Supply voltage was set to a constant value.

2

Supply voltage state is controlled by the ME and depends on parameter data

 

set of the selected audio mode.

Notes

The programmable power supply of the MICP2 line gives you greater flexibility in connecting audio accesso- ries or using MICP2 for a variety of functions other than audio. A detailed description of the extended usage of MICP2 can be found in [7].

The microphone can be muted or activated in all audio modes (1 to 6) and during a voice call only. See AT^SNFS for more details on the various audio modes. As alternative, you can use the AT+CMUT command to mute the microphone.

During an active call, users should be aware that when they switch back and forth between different audio modes (for example handsfree on/off) the value of <MicSwitch> does not change, i.e. the microphone mode is retained until explicitly changed.

MC55_ATC_V01.05

Page 409 of 469

2/10/04

Confidential / Released

 

 

Page 409
Image 409