MC55 AT Command Set

1.8 Common PCN Handset Specification (CPHS)

s

mobile

1.8Common PCN Handset Specification (CPHS)

The ME provides features to implement a device following the prerequisites of the Common PCN Handset Spec- ification (CPHS) Phase 2.

CPHS Feature

Description/Remarks

AT command

Alternate Line Service

Using two phone numbers with one SIM card.

AT^SALS

Voice Message Waiting

Indicate the receipt of a short message coded as Voice Mes-

AT^SIND,

Indication

sage Waiting Indicator as defined by the CPHS Phase 2

AT+CMER, indicators

 

standard.

"vmwait1" and

 

 

"vmwait2"

Operator (Service pro-

Read specific Elementary Files (6F14h, 6F18h) from SIM.

AT+CRSM

vider) name from SIM

 

 

Network and Service Pro-

Lock/Unlock an ME to specific HPLMN and service provider.

AT+CLCK,

vider Lock

 

(AT+CPIN)

Call Forwarding

Get and set diverted call status. Access specific Elementary

AT+CCFC, AT+CRSM

 

File (6F13h) from SIM.

 

Customer Service Profile

Setting services and their menu entries depending on cus-

AT+CRSM

(CSP)

tomer profiles.

 

Information numbers

Hierarchically structured service numbers phonebook on

AT+CRSM

 

SIM according to CPHS 4.2 (mandatory).

 

 

 

 