MC55 AT Command Set

11.6 AT+FCLASS

s

mobile

11.6

AT+FCLASS Fax: Select, read or test service class

Syntax

Test Command

AT+FCLASS=?

Response(s)

(list of supported <n>s)

OK

Read Command

AT+FCLASS?

Response(s)

<n>

OK

Write Command

AT+FCLASS=<n>

Response(s)

OK

PIN ASC0 ASC1 MUX1 MUX2 MUX3

￿ ￿ ￿ ￿ ￿ ￿

Reference(s)

EIA/TIA-592-A

Command Description

The ME is set to a particular mode of operation (data, fax). This causes the MA to process information in a man- ner suitable for that type of information.

Parameter Description

<n>(num)(&W)(&V)

[0](&F)

data (e.g. EIA/TIA-602 or ITU V.25ter)

1

Fax class 1 (EIA/TIA-578-A, Service Class 1)

2

Fax class 2 (EIA/TIA SP-2388, an early draft version of EIA/TIA-592-A - Ser-

 

vice class 2.1)

Notes

Using Error Correcting Mode (ECM) when sending FAXes over GSM should be avoided

MC55_ATC_V01.05

Page 288 of 469

2/10/04

Confidential / Released

 

 

Page 288
Image 288
Siemens MC55 manual At+Fclass=?, At+Fclass?, AT+FCLASS=n, EIA/TIA-592-A