2.11 AT+CMEE

s

mobile

2.11AT+CMEE Report mobile equipment error

Syntax

Test Command

AT+CMEE=?

Response(s)

+CMEE: (list of supported<n>s)

OK

Read Command

AT+CMEE?

Response(s)

+CMEE: <n>

OK

Write Command

AT+CMEE=<n>

Response(s)

OK ERROR

+CME ERROR: <err>

PIN ASC0 ASC1 MUX1 MUX2 MUX3

￿ ￿ ￿ ￿ ￿ ￿

Reference(s)

GSM 07.07

Command Description

This command controls the presentation of the result code +CME ERROR: <err> that indicates errors relating to ME functionality.

When you power down or reset the ME with AT+CFUN=1,1 the setting will be reset to its default. The levels 1 or 2 need to be selected every time you reboot the ME, or may be included, for permanent use, in the user profile saved with AT&W.

Parameter Description

<n>(num)(&W)(&V)

 

0(&F)

disable result code (only 'ERROR' will be displayed)

 

1

enable result code and use numeric values

 

2

enable result code and use verbose values

 

 

 

 

 