MC55 AT Command Set

2.6 ATX

s

mobile

2.6ATX Set CONNECT result code format and call monitoring

Syntax

Exec Command

ATX[<value>]

Response(s)

OK

PIN ASC0 ASC1 MUX1 MUX2 MUX3

￿ ￿ ￿ ￿ ￿ ￿

Reference(s)

V.25ter

Command Description

This parameter setting determines whether or not the TA detects the presence of dial tone and busy signal and whether or not TA transmits particular result codes.

Parameter Description

<value>(num)(&W)(&V)

[0]

CONNECT result code only returned, dial tone and busy detection are both dis-

 

abled.

1

CONNECT <text> result code only returned, dial tone and busy detection are

 

both disabled.

2

CONNECT <text> result code returned, dial tone detection is enabled, busy

 

detection is disabled.

3

CONNECT <text> result code returned, dial tone detection is disabled, busy

 

detection is enabled.

4(&F)

CONNECT <text> result code returned, dial tone and busy detection are both

 

enabled.

MC55_ATC_V01.05

Page 37 of 469

2/10/04

Confidential / Released

 

 

Page 37
Image 37
Siemens MC55 manual ATX Set Connect result code format and call monitoring, ATXvalue