MC55 AT Command Set
2.6 ATX s
m
obil
e
MC55_ATC_V01.05 Page 37 of 469 2/10/04
Confidential / Released
2.6 ATX Set CONNECT result code format and call monitoring
Syntax
Command Description
This parameter setting determines whether or not the TA detects the prese nce of dial tone and busy signal and
whether or not TA transmits particular result codes.
Parameter Description
[0] CONNECT result code only returned, dial tone and busy detection are both dis-
abled.
1 CONNECT <text> result code only returned, dial tone and busy detection are
both disabled.
2 CONNECT <text> result code returned, dial tone detection is enabled, busy
detection is disabled.
3 CONNECT <text> result code returned, dial tone detection is disabled, busy
detection is enabled.
4(&F) CONNECT <text> result code returned, dial tone and busy detection are both
enabled.
Exec Command
ATX[<value>]
Response(s)
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % % % % %
Reference(s)
V.25ter
<value>(num)(&W)(&V)