MC55 AT Command Set

2.8 AT+CFUN

s

mobile

2.8.1Wake up the ME from SLEEP mode

A wake-up event is any event that causes the ME to draw current. Depending on the selected mode, the wake- up event either switches the SLEEP mode off and takes the ME back to full functionality AT+CFUN=1, or activates the ME temporarily without terminating the selected SLEEP mode.

Definitions of the state transitions described in Table 2.3:

Quit: ME exits SLEEP mode.

Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time after the last character was sent or received on the serial interface.

No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.

Table 2.3: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes

Event

Selected mode:

Selected mode:

Selected mode:

 

<fun>=0

<fun>=5 or 6

<fun>=7 or 8 or 9

 

 

 

 

Ignition line

No effect

No effect

No effect

/RTS0 or /RTS1 activation

Quit

No effect (RTS is only

Mode 7 and 8: No effect

 

 

used for flow control)

(RTS is only used for flow

 

 

 

control)

 

 

 

Mode 9: Temporary

Unsolicited Result Code

Quit

Quit

Temporary

(URC)

 

 

 

Incoming voice or data

Quit

Quit

Temporary

call

 

 

 

Any AT command (incl.

Not possible (UART dis-

Temporary

Temporary

outgoing SMS, voice or

abled)

 

 

data call)

 

 

 

Incoming SMS (AT+CNMI

No effect

No effect

No effect

is set to 0,0 (this is the

 

 

 

default setting)

 

 

 

Incoming SMS (AT+CNMI

Quit

Quit

Temporary

is set to 1,1)

 

 

 

GPRS data transfer

Not possible (UART dis-

Temporary

Temporary

 

abled)

 

 

RTC alarm line

Quit

Quit

Temporary

AT+CFUN=1

Not possible (UART dis-

Quit

Quit

 

abled)

 

 

 

 

 

 

MC55_ATC_V01.05

Page 43 of 469

2/10/04

Confidential / Released

 

 

Page 43
Image 43
Siemens MC55 manual Wake up the ME from Sleep mode, Fun=0, Urc