MC55 AT Command Set
8.7 AT^MONP s
m
obil
e
MC55_ATC_V01.05 Page 201 of 469 2/10/04
Confidential / Released
8.7 AT^MONP Monitor neighbour cells
Syntax
Command Description
This command can be used to obtain information of up to six neighbour cells on request.
This command can be used to retrieve information of up to six neighbour cells automatical ly every n seconds.
To stop the presentation type "at" or "AT".
Parameter Description
Display period in seconds
1...254
Note
Due to the fact that not all necessary information of the nei ghbour cells can be decoded during a connection,
Test Command
AT^MONP=?
Response(s)
^MONP:(list of supported <period>s)
OK
Exec Command
AT^MONP
Response(s)
See: 8.7.1
OK
Write Command
AT^MONP=<period>
Response(s)
See: 8.7.1
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % % % % %
Reference(s)
SIEMENS
<period>(num)