Siemens MC55 manual 18.2 ATS3 Write command line termination character, ATS3?, ATS3=n

Models: MC55

1 469
Download 469 pages 30.84 Kb
Page 440
Image 440

MC55 AT Command Set

18.2 ATS3

s

mobile

18.2ATS3 Write command line termination character

Syntax

Read Command

ATS3?

Response(s)

<n>

OK

Write Command

ATS3=<n>

Response(s)

OK

PIN ASC0 ASC1 MUX1 MUX2 MUX3

￿ ￿ ￿ ￿ ￿ ￿

Reference(s)

V.25ter

Command Description

This parameter setting determines the character recognized by TA to terminate an incoming command line.

Parameter Description

<n>(num)(&W)(&V)

command line termination character 000...13(&F)...127

Note

Using other value than 13 may cause problems when entering commands.

MC55_ATC_V01.05

Page 440 of 469

2/10/04

Confidential / Released

 

 

Page 440
Image 440