MC55 AT Command Set

2.3 AT&W

s

mobile

2.3

AT&W Stores current configuration to user defined profile

Syntax

Exec Command

AT&W[<value>]

Response(s)

OK

ERROR/+CME ERROR <err>

 

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

 

 

￿

￿

￿

￿

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference(s)

V.25ter

Command Description

TA stores the currently set parameters to a user defined profile in the non-volatile memory.

Parameter Description

<value>(num)

[0]

Number of profile

Notes

The user defined profile will be restored automatically after PowerUp. Use ATZ to restore user profile and AT&F to restore factory settings. Until the first use of AT&W, ATZ works as AT&F.

User defined profiles in multiplex mode:

AT&W stores the current setting of each channel to the user profile, no matter on which of the three channels the command is executed. Each channel may have an individual profile.

A list of parameters stored to the user profile can be found in Chapter AT Command Settings storable with AT&W.

MC55_ATC_V01.05

Page 33 of 469

2/10/04

Confidential / Released

 

 

Page 33
Image 33