MC55 AT Command Set

16.15 AT^SNFS

Parameter Description

<audMode>(num)(^SNFW)

s

mobile

[1]

Audio mode 1: Standard mode optimized for the reference handset, that can

 

be connected to the analog interface 1 (see your "Hardware Interface Descrip-

 

tion" for information on this handset.) To adjust the volume use the knob of the

 

reference handset. In audio mode 4, this handset can be used with user

 

defined parameters.

 

Note: The default parameters are determined for type approval and are not

 

adjustable with AT commands.

 

AT^SNFD restores <audMode> 1.

2

Audio mode 2: Customer specific mode for a basic handsfree device (Siemens

 

Car Kit Portable).

 

Analog interface 2 is assumed as default.

3

Audio mode 3: Customer specific mode for a mono-headset.

 

Analog interface 2 is assumed as default.

4

Audio mode 4: Customer specific mode for a user handset.

 

Analog interface 1 is assumed as default.

5

Audio mode 5: Customer specific mode.

 

Analog interface 1 is assumed as default.

6

Audio mode 6: Customer specific mode.

 

Analog interface 2 is assumed as default.

Notes

The write command can be used during a voice call to switch back and forth between different modes. This allows the user, for example, to switch handsfree operation on and off.

Users should be aware that <outStep> is a global setting. This means, when another audio mode is selected during a call, the value of <outStep> does not change. This is also true for mute operation which can be set with AT^SNFM or AT+CMUT: If the microphone is muted and the user selects another audio mode during the call, then the microphone remains muted until explicitly changed. Exception: In audio mode 1 <outStep>=4 is fix.

MC55_ATC_V01.05

Page 414 of 469

2/10/04

Confidential / Released

 

 

Page 414
Image 414
Siemens MC55 manual Atsnfd restores audMode