Appendix A Troubleshooting

CPSEE_TSP500 Hard Drive Diagnostic

All CPSEE_TSP500’s are installed with an IDE Smart Drive test/reporting tool. This tool reports the status of the specified IDE Smart Drive.

Instructions

1.Login to “root

2.Type: ide-smart /dev/hda

The following is an example of the output:

[root@tspdev2 root]# ide-smart /dev/hda

Value=100

Threshold= 46

Passed

Id=

1

Status=15

{Prefailure

Online }

Id=

2

Status= 5

{Prefailure

OffLine}

Value=100

Threshold= 30

Passed

Id=

3

Status= 3

{Prefailure

Online }

Value=100

Threshold= 25

Passed

Id=

4

Status=50

{Advisory

Online }

Value=100

Threshold=

0

Passed

Id=

5

Status=51

{Prefailure

Online }

Value=100

Threshold= 24

Passed

Id=

7

Status=15

{Prefailure

Online }

Value=100

Threshold= 47

Passed

Id=

8

Status= 5

{Prefailure

OffLine}

Value=100

Threshold= 19

Passed

Id=

9

Status=50

{Advisory

Online }

Value= 96

Threshold=

0

Passed

Id= 10

Status=19

{Prefailure

Online }

Value=100

Threshold= 20

Passed

Id= 12

Status=50

{Advisory

Online }

Value=100

Threshold=

0

Passed

Id=192

Status=50

{Advisory

Online }

Value=100

Threshold=

0

Passed

Id=193

Status=50

{Advisory

Online }

Value= 98

Threshold=

0

Passed

Id=194

Status=34

{Advisory

Online }

Value=100

Threshold=

0

Passed

Id=195

Status=26

{Advisory

Online }

Value=100

Threshold=

0

Passed

Id=196

Status=50

{Advisory

Online }

Value=100

Threshold=

0

Passed

Id=197

Status=18

{Advisory

Online }

Value=100

Threshold=

0

Passed

Id=198

Status=16

{Advisory

OffLine}

Value=100

Threshold=

0

Passed

Id=199

Status=62

{Advisory

Online }

Value=200

Threshold=

0

Passed

Id=200

Status=15

{Prefailure

Online }

Value=100

Threshold= 60

Passed

OffLineStatus=0 {NeverStarted},

AutoOffLine=No, OffLineTimeout=7

minutes

OffLineCapability=123 {Immediate Auto SuspendOnCmd}

 

AutoSave}

SmartRevision=16, CheckSum=221,

SmartCapability=3 {SaveOnStandBy

Note:

If while your logged into a TSP, you notice any unsolicited messages referencing “I/O Error”, or you receive “I/O errors” in response to any commands, DO NOT reboot the TSP, and contact Engi- neering immediately.

The last column will show whether a specific test Passed, or Failed. If a test “Fails”, arrangements should be made to replace the hard drive as soon as possible. Engineering should also be notified.

Page A-4

Version 4.0

CPSEE_TSP500 User Guide

 

This document is confidential and proprietary to SER Solutions and is not for external use.

Page 210
Image 210
Avaya CPSEE_TSP500 manual CPSEETSP500 Hard Drive Diagnostic, Instructions, Login to root, Type ide-smart /dev/hda