Chapter 4 Features and Enhancements
assigned.
•The Admin Terminal command “spstuff" displays “Monitor has Assigned Station List”, if a monitor has been restricted via the MONITOR_ASSIGN keyword.
Enter | sp 169 |
| ||
Station # 169 | Matrix: 0000082c | |||
mvip: | board: 0 | st: 9 | ts: 20 | |
local: board: 3 | st:28 | ts: 0 | ||
Dsp | 1189 Assigned |
|
| |
Dsp is listening to MTX 82c |
|
Queue = stinact
Digital Station (trunk=937)
Phone On Hook
This Station has Manual | Monitor Capability | ||
Monitor has Assigned Station | List | ||
sflags = [8100] | tflags | = [0] | zflags = [0] |
preview queue: | current: 0 | Peak: 0 |
Decibel Level Adjustment - Feature
When performing Client Monitoring, the audio level of the monitored call tends to be lower than that of the Client, and Supervisor. A new keyword has been added to the Dialing Rules (CLIMON_GAIN) that will specify some decibel level to increase the volume of the monitored call. The default gain at present is 6db. If customers are complaining of low volume when doing Cli- ent Monitoring, add this keyword and type “load all” in the Admin Terminal. The range of adjustment is 0db through 12db.
Example: CLIMON_GAIN 9
The above assignment would raise the volume of the monitored call by 9db.
Page
This document is confidential and proprietary to SER Solutions and is not for external use.