Keyword | Default | Admin | Description | |
Terminal | ||||
|
|
| ||
|
|
|
| |
VOICE_TONE_RATIO | 393216 | voice_ratio | Used to discriminate between tone | |
|
|
| and voice | |
|
|
|
| |
VOICE_NOICE_LEVEL | 81920 | voice_noise | Do not adjust | |
|
|
|
| |
VOICE_LEAKAGE_TIME | 8 | voice_leakage | Do not adjust | |
|
|
|
| |
VOICE_TIME1 | 60 | voice_time | Voice Qualification time 1 (millisec- | |
|
|
| onds) | |
|
|
|
| |
VOICE_TIME2 | 60 | voice_time | Voice Qualification time 2 (millisec- | |
|
|
| onds) | |
|
|
|
| |
TONE_TIME1 | 60 | tone_time | Tone Qualification time 1 (millisec- | |
|
|
| onds) | |
|
|
|
| |
TONE_TIME2 | 80 | tone_time | Tone Qualification time 2 (millisec- | |
|
|
| onds) | |
|
|
|
| |
VOICE_ANSM_MLENGTH | 1600 | voice_length | Duration of voice for a Medium Event | |
|
|
|
| |
VOICE_ANSM_LENGTH | 2200 | voice_length | Duration of voice for Answering | |
|
|
| Machine | |
|
|
|
| |
VOICE_SILENCE_TIME | 900 | silence_time | Duration of silence after voice for a | |
|
|
| live connect (milliseconds) | |
|
|
|
| |
VOICE_SILENCE_LEVEL | 33 | silence_db | Silence threshold in decibels | |
|
|
| (assumed negative) | |
|
|
|
| |
ANSM_TIMEOUT | 8 | If beep not heard within this time, play | ||
|
|
| Encore anyway (seconds) | |
|
|
|
| |
ANSM_SILENCE | 20 | Start Playing Encore to Answering | ||
|
|
| Machine after this period – once a | |
|
|
| beep is heard (100ms tics. 20 = 2 | |
|
|
| seconds) | |
|
|
|
| |
PAMD_METHOD | 0 | 1 = old method, 0 = new method | ||
|
|
|
|