Chapter 6 Trunk Spans and Dialing Rules

machine. The default is 2200 milliseconds (2.2 seconds), and should not be changed unless advised to do so by Engineering.

VOICE_ANSM_MLENGTH

This keyword specifies (in milliseconds) the minimum length of time contin- uous voice must be detected before classifying the call to be an answering machine. The default is 1600 milliseconds (1.6 seconds), and should not be changed unless advised to do so by Engineering. See keyword

PAMD_METHOD.

VOICE_LEAKAGE_TIME

This keyword allows changing the noise level. The default is 81920.

Caution!

This item is intended for engi- neering use, and should not be modified unless instructed to by engineering.

VOICE_NOISE_LEVEL

This keyword allows changing the leakage time variable. The default is 8.

Caution!

This item is intended for engi- neering use, and should not be modified unless instructed to by engineering.

VOICE_SILENCE_LEVEL

This keyword specifies the maximum decibel level that is considered to be silence. The value entered is assumed to be negative. The default is 33db, and should not be changed unless advised to do so by Engineering.

VOICE_SILENCE_TIME

This keyword specifies (in milliseconds) the minimum length of a silence after voice has been detected before call analysis reports that live voice has ended. The default is 800 milliseconds, and should not be changed unless advised to do so by Engineering.

VOICE_TIME1 and VOICE_TIME2

Caution!

This item is intended for engi- neering use, and should not be modified unless instructed to by engineering.

These keywords control the minimum voice time needed before voice begin event is sent.

VOICE_TONE_RATIO

CPSEE_TSP500 User GuideVersion 4.0Page 6-19

This document is confidential and proprietary to SER Solutions and is not for external use.

Page 133
Image 133
Avaya CPSEE_TSP500 manual Voiceansmmlength, Voiceleakagetime, Voicenoiselevel, Voicesilencelevel, Voicesilencetime