2-36 Command Line Interface Commands Reference

Virtual LAN (VLAN) configuration commands

Note: See also “RADIUS Authentication Profile configuration commands” on page 2-39 and “Additional LAN configuration command” on page 2-16.

VLAN Configuration Commands

vlan id by [ port-based global ] no vlan id

vlan id name name

vlan id network { none lan eth2 eth3 eth4 eth5 eth6 eth7 }

vlan id id { 1 .. 4094 } (supported in V8.6.1)

vlan id 8021x authprofile { authprofile tag name authprofile id } no vlan id 8021x authprofile

vlan id interface eth { 1 2 0/1 0/...n } tag { yes no } [ tos-priority { off on -} ]

[ iptos-promote { off on } ] [ authprofile { name id } ]

[ inter-vlan-routing { group-1...group-8 } enable { yes no } ] no vlan id interface eth { 1 2 0/1 0/...n }

vlan id interface ssid n tag { yes no } no vlan id interface ssid n

vlan id interface usb 0 tag { yes no } no vlan id interface usb 0

vlan id interface cp n tag { yes no } no vlan id interface cp n

show config vlan { id }

vlan id by [ port-based global ] no vlan id

These commands allow you to create or delete a VLAN specified by id and designate it either port-basedor global. You can create up to 16 VLANs.

Page 48
Image 48
Netopia CLI 874 manual Virtual LAN Vlan configuration commands