6.3.3 Initialization at power-ON

The carriage moves to its home position and performs the peak detection. Then it moves to the carriage waiting position and waits.

Power-ON

Carriage home position sensor

ONNO

YES

Scan motor rotating (Moves to the forward direction of carriage)

Carriage home

NO position sensor

OFF

YES

Carriage home position

data set

Deceleration Stop

Moving peak detection

position

Peak detection

Completion of

initialization

Moving to carriage

waiting position

Scanning command

Scan motor rotating (Moves to backward direction of carriage)

Carriage home position sensor

ON NO

YES

Deceleration Stop

Fig. 6-303