16

(2) IH error

Checking timing

Error content

Port input value

Error code

 

 

H1ERR1

H1ERR2

 

 

 

 

 

 

 

 

Power ON

Initial abnormality

L

L

C470

 

 

 

 

 

In warming up

IH power voltage abnormality

L

L

C470

 

 

 

 

 

Detecting 40°C

IGBT high temperature abnormality /

L

H

C480

 

Continuous energization (15 sec.)

 

 

 

 

 

 

 

 

 

 

IH circuit/coil abnormality

H

H

C490

 

 

 

 

 

In warming up

IH power voltage abnormality

L

L

C470

 

 

 

 

 

Detecting 40°C

IGBT high temperature abnormality /

L

H

C480

During ready status

Continuous energization (15 sec.)

 

 

 

 

 

 

 

 

 

IH circuit/coil abnormality

H

H

C490

 

 

 

 

 

During ready status

IH power voltage abnormality

L

L

C470

 

 

 

 

 

During printing

IGBT high temperature abnormality /

L

H

C480

At Energy Saving Mode

Continuous energization (15 sec.)

 

 

 

 

 

 

 

 

 

IH circuit/coil abnormality

H

H

C490

 

 

 

 

 

 

Normal

H

L

-

 

 

 

 

 

Initial abnormality:

CPU (IH) abnormality is not cleared.

IH power voltage abnormality:

The input voltage becomes above 20% (approx.) or below 20% (approx.) of the rated voltage.

IGBT high temperature abnormality:

Overheating of IGBT or short- or open-circuit of IGBT temperature-detecting sensor.

IH circuit abnormality:

Abnormality in IH circuit

IH coil abnormality:

Temperature-detecting sensor in IH circuit is abnormal, or IH coil is open-circuited or wrongly in- stalled.

e-STUDIO3511/4511 FUSER UNIT/PAPER EXIT SECTION 16 - 14

November 2003 © TOSHIBA TEC

Page 292