14

(8) Remove 3 conductive tapes.

Note: When assembling, use the new conductive tape. Also, attach the conductive tape to the transfer belt cleaning blade referring to the figure on the right.

(9)Remove 2 screws and take off the transfer belt cleaning blade.

Notes: 1. Make sure not to touch or damage the edge of the blade.

2.Check the color deviation after replacing the transfer belt cleaning blade.

Conductive tape

Fig. 14-729

47 mm

160 mm

 

41 mm

Fig. 14-730

Cleaning blade

Fig. 14-731

[H]Transfer belt cleaner auger motor / Transfer belt cleaner clutch

(1)Take off the transfer belt cleaning unit ( Chapter 14.7 [F]).

(2)Separate the transfer belt cleaning unit into 2 parts.

( Chapter 14.7 [G]).

(3)Release the latch and take off the gear.

Gear

Fig. 14-732

e-STUDIO3511/4511 TRANSFER/TRANSPORT UNIT

14 - 14

November 2003 © TOSHIBA TEC

04/10

Page 268
Image 268
Toshiba 3511, 4511 manual Conductive tape