[D]Automatic original detection sensor (APS sensor)

(D-1) A4 series

(1)Remove the original glass ( Chapter 6.7 [A]).

(2)Disconnect 1 connector and remove 1 screw for each APS sensor. Take off 5 APS sensors.

(D-2) LT series

(1)Remove the original glass ( Chapter 6.7 [A]).

(2)Disconnect 1 connector and remove 1 screw for each APS sensor. Take off 4 APS sensors.

[E] Exposure lamp

(1)Remove the original glass and take off the front upper cover ( Chapters 6.7 [A], 2.5.1 [I]).

(2)Move the carriage-1 to the center position where the side of the frame is cut out.

(3)Disconnect the connector of the exposure lamp. Note: When disconnecting the connector, pay attention not to give load to the carriage

frame.

(4)Remove 1 screw.

(5)Lift up the front side of the exposure lamp and take off by sliding it.

APS sensor

Fig. 6-705-1

APS sensor

Fig. 6-705-2

Connector

Fig. 6-706

Exposure lamp

Fig. 6-707