e-STUDIO3511/4511 SCANNER 6 - 20 November 2003 © TOSHIBA TEC
6
(6) Remove 2 screws and take off the inverter
board.
Mirror-1
Inverter board
Notes:1. When installing carriage-1, fix the bracket
temporarily at the position (A). Then move
it to the direction (B), push it to the end
and fix securely.
2.Refer to the Service Handbook for more
details.
(A)
(A)
(B)
Fig. 6-717
Fig. 6-718
(5) Take off the carriage-1 while inclining it.
Note: When replacing the mirror-1, replace the
carriage-1 together with mirror-1.
Mirror-1 should not be removed.
Carriage-1
Fig. 6-716
(4) Remove the square seal fixing the lamp cable
to the base. Release the harness from the
harness clamp. Disconnect the connector of the
lamp cable from the SLG board.
Fig. 6-715