November 2003 © TOSHIBA TEC 6 - 21 e-STUDIO3511/4511 SCANNER
6
Notes: 1.When installing carriage-2, fix the bracket
temporarily at the position (A). Then
move it to the direction (B), push it to the
end and fix securely.
2.Refer to the Service Handbook for more
details.
(A)
(B)
(A)
(7) Attach the wire holder jigs to the pulleys to
prevent the wires from loosening.
Note: Refer to “3.9 Adjustment of the Scanner
Section” in the Service Handbook for the
direction of the wire holder jigs.
(8) Detach the tension springs of the front and rear
sides.
(9) Remove the carriage wires.
Tension spring
Carriage wire
Fig. 6-719
(10)Take off the carriage-2 while its corner is
pushed into the window of the rail and inclining
the carriage.
Note: When replacing the mirrors-2 and -3, replace
the carriage-2 together with mirrors-2 and -3.
Mirrors-2 and -3 should not be removed.
Carriage-2
Fig. 6-720
Fig. 6-721
Fig. 6-722