(4)Remove the harness clamp. Remove 1 screw and take off the transfer belt cleaner auger motor with the whole bracket.

(5)Remove 2 screws and take off the transfer belt cleaner auger motor from the bracket.

Harness clamp

Fig. 14-733

Transfer belt cleaner auger motor

(6)Remove 1 clip and take off 1 bushing. Then take off the assembly of the shaft and clutch.

(7)Remove 1 clip. Remove 1 E-ring and take off the bushing-1, and then take off the bushing- 2 with the shaft. Take off the transfer belt cleaner clutch.

Fig. 14-734

Shaft

Clutch

Fig. 14-735

Bushing-2

Transfer belt

 

cleaner clutch

Clip

 

 

Bushing-1

 

E-ring

Fig. 14-736

 

14

November 2003 © TOSHIBA TEC

14 - 15

e-STUDIO3511/4511 TRANSFER/TRANSPORT UNIT

04/10

Page 269
Image 269
Toshiba 4511, 3511 manual Harness clamp Transfer belt cleaner auger motor