16

16.4.3 IH control circuit interface

The IH control circuit uses a photocoupler as an insulation against the secondary circuit. The interface signals are as follows.

CN No.

Name of single

Direction

Definition

 

 

 

 

CN455-2

+5VSW

 

 

 

 

 

 

CN455-3

H1PWR1

LGC to IH

Switching signal of power setting

 

 

 

 

CN455-4

H1PWR2

 

 

 

 

 

 

CN455-5

H1PWR3

 

 

 

 

 

 

CN455-6

H2PWR1

 

 

 

 

 

 

CN455-7

H2PWR2

 

 

 

 

 

 

CN455-8

H2PWR3

 

 

 

 

 

 

CN455-1

IH2 ON

LGC to IH

IH coil energization permitting signal

 

 

 

 

CN456-1

IH1 ON

 

 

 

 

 

 

CN456-4

H1ERR1

IH to LGC

IH status signal (*Note)

 

 

 

 

CN456-5

H1ERR2

 

 

 

 

 

 

CN456-2

SG

 

 

 

 

 

 

CN456-3

IHDUTY

LGC to IT

Main/sub switching signal

 

 

 

 

(*Note) IH status signal

When the temperature (due to insufficient cooling) of the switching element (IGBT) is abnormal:

“12: Coil is abnormal, IH FAN OFF” After a certain period of time Error [C480]

Main/sub coil continuous energization error (15 sec.): “12: Coil is abnormal, IH FAN OFF” After a certain period of time Error [C480]

When the upper limit of the power voltage is abnormal:

“10, 11, 14: Initializing” After a certain period of time Error [C470]

“07: Ready” After a certain period of time Error [C470]

When the lower limit of the power voltage is abnormal:

“10, 11, 14: Initializing” After a certain period of time Error [C470]

“07: Ready” After a certain period of time Error [C470]

Defective circuits : “13: Abnormal circuit, IH coil abnormality” Error [C490]

Ready state after the initialization: “01: Ready”

e-STUDIO3511/4511 FUSER UNIT/PAPER EXIT SECTION 16 - 6

November 2003 © TOSHIBA TEC

Page 284
Image 284
Toshiba 3511, 4511 manual IH control circuit interface, +5VSW, IH2 on, IH1 on, Ihduty