16

(7) Abnormality detection by the thermistors

The following table shows the conditions judging the fuser belt temperature abnormality and detecting timing.

Checking timing

Condition

 

Temperature judged

 

Checking

Error

 

 

 

 

 

 

Main thermistor

 

Sub thermistor

Front edge thermistor

timing

code

 

 

 

 

 

 

 

 

 

 

 

Power ON

1

250°C or above

 

-

-

 

C440

 

 

 

 

 

 

 

-

 

250°C or above

-

Power ON

 

 

 

 

 

 

 

 

 

 

 

 

2

40°C or below

 

150°C or above

-

C410

 

 

 

 

 

 

 

 

 

 

150°C or above

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detecting

1

250°C or above

 

-

-

 

C440

40°C

 

 

 

 

 

-

 

250°C or above

-

Fixed time

 

 

 

 

 

 

 

 

 

 

 

2

40°C or below

 

-

-

C410

 

 

 

 

 

 

 

 

 

 

-

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detecting

 

250°C or above

 

-

-

 

 

100°C

 

 

 

 

 

 

 

1

-

 

250°C or above

-

 

C440

 

 

 

 

 

 

 

100°C or below

 

-

-

Fixed time

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

100°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

40°C or below

 

150°C or above

-

 

C430

 

 

 

 

 

 

 

150°C or above

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detecting

 

250°C or above

 

-

-

 

 

160°C

 

 

 

 

 

 

 

1

-

 

250°C or above

-

 

C440

 

 

 

 

 

 

 

160°C or below

 

-

-

Fixed time

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

160°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

40°C or below

 

150°C or above

-

 

C430

 

 

 

 

 

 

 

150°C or above

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detecting

 

250°C or above

 

-

-

 

 

ready

 

 

 

 

 

 

 

1

-

 

250°C or above

-

 

C440

temperature

 

 

 

 

 

Ready temp. or below

 

-

-

Fixed time

 

 

 

 

 

 

 

 

 

 

 

 

-

 

Ready temp. or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

40°C or below

 

160°C or above

-

 

C430

 

 

 

 

 

 

 

160°C or above

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

During ready

 

250°C or above

 

-

-

 

 

status

 

 

 

 

 

 

 

1

-

 

250°C or above

-

 

C440

At energy

 

 

 

 

 

40°C or below

 

-

-

On usual

 

 

 

saving mode

 

 

 

 

 

 

 

-

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

40°C or below

 

160°C or above

-

 

C430

 

 

 

 

 

 

 

160°C or above

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

During printing

 

250°C or above

 

-

-

 

 

 

 

 

 

 

 

 

 

 

 

-

 

250°C or above

-

 

 

 

 

 

 

 

 

 

 

 

1

-

 

-

250°C or above

On usual

C440

 

 

 

 

 

 

 

 

 

 

40°C or below

 

-

-

 

 

 

 

 

 

 

 

 

 

 

 

-

 

40°C or below

-

 

 

 

 

 

 

 

 

 

 

 

2

-

 

-

40°C or below

 

C450

 

 

 

 

 

 

 

 

At paper jam

1

250°C or above

 

-

-

On usual

C440

 

 

 

 

 

 

 

2

-

 

250°C or above

-

 

 

 

 

 

 

 

 

 

 

 

 

* Condtion: Priority of error checking.

e-STUDIO3511/4511 FUSER UNIT/PAPER EXIT SECTION 16 - 12

November 2003 © TOSHIBA TEC

Page 290
Image 290
Toshiba 3511, 4511 manual Condtion Priority of error checking