(2) Discharge the developer material.

(3) Pour the developer material.

(B-2) Doctor blade

(1)Discharge the developer material ( Chapter 12.8 (B-1)).

(2)Remove the urethan seal.

(3)Remove 2 screws and take off the doctor blade.

(B-3) Developer sleeve

(1)Discharge the developer material ( Chapter 12.8 (B-1)).

(2)Remove the urethan seal ( Chapter 12.8 (B-2)).

(3)Front side: Remove 1 screw and take off the polarity adjustment plate.

Note: Before disassembling, record (mark if any) the scale pointed by the polarity adjustment lever. Then match the polarity adjustment plate at the scale previously recorded when reassembling.

Fig. 12-821

Fig. 12-822

Urethan seal

Doctor blade

Fig. 12-823

Polarity adjustment plate

Fig. 12-824