Accessories

Control Panel

 

7

8

6

 

 

9

 

 

 

 

 

 

 

 

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

Figure 6-13

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

 

 

Function

 

 

 

 

 

 

1

 

Ready light

The Ready light blinks during initialization and is constant when the EHCS is in use

 

 

 

or in standby mode.

 

 

 

 

 

 

 

 

 

2

 

Sample set

Press to have the EHCS deliver the next collated set to the top tray.

 

 

 

button

 

 

 

 

 

 

 

 

 

3

 

Unload

Press once to lower the Stacker Tray and unlock the front door. If pressed while

 

 

button

running a job, all sheets in the paper path are delivered before the Stacker Tray

 

 

 

starts to lower.

 

 

 

 

 

 

 

 

4

 

Unload light

Illuminates when the Stacker Tray has reached the down position and the front door

 

 

 

can be opened.

 

 

 

 

 

 

 

 

 

 

5

 

Wait light

Blinks when the Stacker Tray is moving up or down.

 

 

 

 

 

 

 

 

6

 

Fault code

Refer to the fault code table later in this section.

 

 

 

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

Top tray jam

Blinks when there is a jam.

 

 

 

 

 

 

area

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Bypass jam

Blinks when there is a jam.

 

 

 

 

 

 

area

 

 

 

 

 

 

 

 

 

 

 

9

 

Stacker tray

Blinks when there is a jam or the door is open.

 

 

 

 

jam area

 

 

 

 

 

 

 

 

 

 

 

Keypad

Used by the service representative for diagnostics (not shown). The keypad is

 

 

 

located on the front right of the control panel.

 

 

 

 

 

 

 

 

 

 

6 Accessories

DocuColor 5252 Operator Manual

6-19

Page 245
Image 245
Xerox 5252 manual Control Panel